HORIBA - ABX Pentra 60 C+

Manufactured by  HORIBA
Follow this Equipment

    Data management on stand-alone PC. Micro-sampling from whole blood (CBC : 30 µL - ...

     
  1. Data management on stand-alone PC. 
  2. Micro-sampling from whole blood (CBC : 30 µL - DIFF: 53 µL)  
  3. Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) - DHSS* Technology. 
  4. Perfect homogenization of blood samples with reagents - MDSS** Technology 
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked byjazipa

Hematology Analyzers Service ProvidersView All (1)

Request Support
Documents & Manuals

There are no Documents or Manuals available.

Features of ABX Pentra 60 C+
  • Throughput: Up to 60 samples/hour 

  • Reagents: Only 4 onboard reagents and 1 diluent 

  • Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology 

  • 3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix. 

  • Basophils counted through specific channel 

  • High resolution matrix includes the determination of 2 additional subpopulations (% and #): Atypical Lymphocytes (ALY) and Large Immature Cells (LIC)  

    DHSS : Double Hydrodynamic Sequential System (HORIBA Medical Patent)  * MDSS : Multi-Distribution Sampling System (HORIBA Medical Patent)  * RUO parameters (Research Use Only)

General Specifications
Power Requirements 100 to 240 V (± 10%) - 50 to 60 Hz.
Weight77 lbs
Additional Specifications

Technical 
Dimensions: 
20.3 x 17.5 x 19 in / 51,5 cm x 44,5 cm x 48 cm 
Printer: 
Laser printer 
Throughput: 
60 tests/hour. 
Data management: 
Colour screen: 15 in. monitor (800 x 600px) 
Windows XP Prof.TM  
User-defined flagging limits 
Transmit patient & QC to LIS 
Uni-directional or bi-directional connection 
Communication Protocols: ABX / ASTM 
CD-ROM drive / Floppy disk 
2 serial ports minimum 
USB Keyboard / USB Mouse 
Memory: 
10,000 results + Graphics 
Quality Control Management: 
12 selectable QC files 
XB: 60 Operator selectable batches with statistics (20 samples per batch) 
Within run 
Levey-Jennings Graphs 
Logs: 
Reagents, calibration, maintenance, errors, blank cycle 
 
Samples 
60 samples/hour (closed tube) 
 
Parameters (26): 
WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# & ALY%*, LIC# & LIC%*, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PCT*, PDW*. 
Graphs: 
High-definition LMNE matrix 
PLT, RBC, WBC/BAS curves. 
Blood Volume: 
CBC mode : 30 µL 
CBC + DIFF mode : 53 µL 
Stability: 
48 hours post-draw stability 
Operating sample mode: 
Closed tube 
Identification: 
Alphanumeric. Bar-code reader (optional) 
 
* RUO parameters (Research Use Only)