HORIBA - ABX Pentra 60 C+
Data management on stand-alone PC. Micro-sampling from whole blood (CBC : 30 µL - ...
- Data management on stand-alone PC.
- Micro-sampling from whole blood (CBC : 30 µL - DIFF: 53 µL)
- Cytochemistry, Impedance (real cell volume measurement) & Optical (analysis of the internal cellular structure by measuring light absorbance) - DHSS* Technology.
- Perfect homogenization of blood samples with reagents - MDSS** Technology
Active Questions & AnswersAsk a Question
Recent Questions & Answers
Asked byjazipa
Hematology Analyzers Service ProvidersView All (1)
Documents & Manuals
There are no Documents or Manuals available.
Features of ABX Pentra 60 C+
Throughput: Up to 60 samples/hour
Reagents: Only 4 onboard reagents and 1 diluent
Perfect differentiation of the 5 WBC sub-populations with DHSS* Technology
3 histograms for RBC, BAS/WBC and PLT together with the 5 DIFF Matrix.
Basophils counted through specific channel
High resolution matrix includes the determination of 2 additional subpopulations (% and #): Atypical Lymphocytes (ALY) and Large Immature Cells (LIC)
DHSS : Double Hydrodynamic Sequential System (HORIBA Medical Patent) * MDSS : Multi-Distribution Sampling System (HORIBA Medical Patent) * RUO parameters (Research Use Only)
General Specifications
Power Requirements | 100 to 240 V (± 10%) - 50 to 60 Hz. |
Weight | 77 lbs |
Additional Specifications
Technical
Dimensions:
20.3 x 17.5 x 19 in / 51,5 cm x 44,5 cm x 48 cm
Printer:
Laser printer
Throughput:
60 tests/hour.
Data management:
Colour screen: 15 in. monitor (800 x 600px)
Windows XP Prof.TM
User-defined flagging limits
Transmit patient & QC to LIS
Uni-directional or bi-directional connection
Communication Protocols: ABX / ASTM
CD-ROM drive / Floppy disk
2 serial ports minimum
USB Keyboard / USB Mouse
Memory:
10,000 results + Graphics
Quality Control Management:
12 selectable QC files
XB: 60 Operator selectable batches with statistics (20 samples per batch)
Within run
Levey-Jennings Graphs
Logs:
Reagents, calibration, maintenance, errors, blank cycle
Samples
60 samples/hour (closed tube)
Parameters (26):
WBC, NEU# & NEU%, LYM# & LYM%, MON# & MON%, EOS# & EOS%, BAS# & BAS%, ALY# & ALY%*, LIC# & LIC%*, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, PCT*, PDW*.
Graphs:
High-definition LMNE matrix
PLT, RBC, WBC/BAS curves.
Blood Volume:
CBC mode : 30 µL
CBC + DIFF mode : 53 µL
Stability:
48 hours post-draw stability
Operating sample mode:
Closed tube
Identification:
Alphanumeric. Bar-code reader (optional)
* RUO parameters (Research Use Only)