Features of ABX Pentra DX 120
  • Methods of measurement: Flow cytometry, Cytochemistry, impedance, absorbance, optical cytometry and fluoro-flowcytometry     
  • QUADIMENSION Concept: Automatic correction of the leukocyte count based on 4 independent principles     
  • DHSS: Focused flow cytometry and sequential measurement (impedance and absorbance)     
  • Automatic reflex testing: Selective and programmable (hematology parameters alarms and flags)     
  • Rack rotation mixing of samples: Smooth and efficient     
  • Liquid valves (no pinch valves): Reliability and increased precision
General Specifications
Depth 22.6 in
Height29.5 in
Width 65 in
Power Requirements 100/240 V - 50/60 Hz
Peak Power2 kW
Weight242.5 lbs
Additional Specifications

Technical     
Printer:     
Laser     
Throughout:     
120 samples/hour     
Data processing:     
Windows XP, Floppy disk,     
CDROM (R/W), RS 232C, TCP/IP,     
2 x USB1 Mono and hi-directional connection     
Compliance:     
ASTM     
Memory capacity:     
80 GB unlimited patient database     
Patient Management:     
Automatic validation (setting rules), Data Check, Patient history (matrix, curves, data), manual entry.     
     
Samples     
Parameters (49):     
WBC, RBC, HGB, HCT, MCV, MCH, MCHC, RDW, PLT, MPV, *PCT, *PDW %, NEU, LYM, MON, EOS, BAS, *ALY, *LIC, *IMM, *IML, *IMG : (% and #), RET (% and #), RETH %, RETM %, RETL %, *IMM %, CRC%, IRF %, MRV, MFI. NRBC % NRBC#, *CWBC, *WBC#, *RBC#, *PolyNuc#, *MonoNuc#     
*RUO (Research Use Only)     
Volume:     
Manual mode : 130 µL     
Automatic mode : 200 µL      
Stability:     
Up to 48 hours for CBC/DIFF     
Operating sample mode:     
Autoloader 15 racks (150 tubes) capacity     
Continuous feed for 8-racks, 160 slides capacity     
Sample mixing with end-over-end rack rotation     
Open tube in STAT mode     
Identification:     
Alphanumeric, Bar-code reader (internal and external)     
Automatic 3-line printing on the slide using indelible ink