Features of DUH-211
  • Evaluation of Hardness and Material Parameters in Accordance with Standards (ISO 14577-1 Annex A)   
  • Highly Precise Evaluation of Elastic Modulus   
  • Low Test Force with Measurement Resolution of 0.196 µN   
  • Ultra-Wide Test Force Range of 0.1 to 1,961 mN   
  • High-Precision Measurement of Indentation Depth   
  • Supports a Wide Range of Testing Methods   
  • Supports Vickers Hardness Test
General Specifications
Depth 405 mm Tester
Height530 mm Tester
Width 355 mm Tester
Power Requirements Single phase, 100±10 V, 50/60 Hz
Peak Power100 W (not including power consumption of PC)
Weight60 kg Tester
Additional Specifications

Loading Method: Electromagnetic coil   
Test Force Range: Full scale of 0.1 to 1,961 mN   
Test Force Accuracy: ±19.6 ΜN or ±1% of displayed test force, whichever is greater   
Minimum Measurement Increment: 0.196 ΜN (for a test force not exceeding 1.96 mN)   
Measurement Method: Differential transformer   
Measurement Range: 0 to 10 Μm   
Minimum Measurement Increment: 0.0001 Μm   
Linearity: ±2% of full scale (20 Μm)   
Type: Triangular pyramid indenter with tip angle of 115°   
(Vickers indenter and Knoop indenter are available as options.)   
Tip Radius: 0.1 Μm max.   
Total Magnification (microscope): x 500   
Objective Lens: x 50 (Up to 2 lenses can be attached.)   
Eyepiece: x 10   
Lighting Method: Reflected illumination   
Light Source (lamp): LED: 3 W, 3 V   
Light-Path Switching: Observation or photograph (selectable)   
Collimation Method: Direct connection between encoder and control handle; synchronized movement of two indexes   
Detector: Optical encoder   
Effective Measurement Range: 200 Μm (with x 50 objective lens)   
Minimum Measurement Increment: 0.01 Μm/pulse   
Vertical Distance: Approx. 60 mm   
Area: Approx. 125 (W) x 125 (L) mm   
Stage Movement Range: 25 mm in both X and Y directions   
Specimen Holder: Specimen dimensions (i.e., 8 (thickness) x 30 (width) mm)   
when thin-type attachment (type 3) is used   
OS: Windows® 2000/XP   
CPU: 1 GHz min.   
Disk Drives: CD-ROM drive and 3.5" floppy disk drive   
Display Resolution: 1024 x 768 min. (recommended)   
Expansion Bus: PCI bus, 2 slots min.   
(Must be possible to insert 175-mm and 120-mm cards.)   
Grounding*: The grounding pins of 3-pin connectors must be connected to a   
resistance of 100 W or less.   
Temperature: Recommended temperature: 23±1°C   
Allowable range: 10°C to 35°C   
Vibration: Horizontal vibration: 0.017 Gal max. (at 10 Hz or more)   
0.01 Μm max. (at less than 10 Hz)   
Vertical vibration: 0.010 Gal max. (at 10 Hz or more)   
0.005 Μm max. (at less than 10 Hz)   
Humidity: 80% max. (no condensation)   
External Dimensions: Control unit: Approx. 315 (W) x 375 (D) x 110 (H) mm   
Weight: Control unit: Approx. 5 kg   
   