Hach Company - DR 3900

Manufactured by  Hach Company
Follow this Equipment

Benchtop Spectrophotometer with RFID* Technology

The proven technology you have come to expect from Hach just got better. Built with the future of water analysis in mind, the DR 3900 will give consistently accurate results in a simpler testing format.

*RFID available only in US, Canada, Australia, New Zealand, Puerto Rico, and Colombia. Customers in other countries should order LPV440.99.00002.
Active Questions & AnswersAsk a Question

Recent Questions & Answers

avatar placemark

Asked byzurik

avatar placemark

Asked bycjoseph2131

UV/VIS Spectrophotometers Service ProvidersView All (32)

Request Support
Features of DR 3900

Guided Procedure The DR 3900 guides you step-by-step through the testing procedure like a GPS, so you can get the accurate results you need every time.

Elimination of False Results Scratched, flawed, or dirty glassware becomes a non-issue when your machine takes 10 readings and eliminates any outliers.

Hands Free Updates RFID* technology automatically updates the program's calibration factors when you place a TNTplusTM chemistry box near the machine.

Flexible Connectivity Built with 1 LAN and 3 USB ports, the DR 3900 easily connects to your computer and is programmed to easily interface with a LIMS system.

Sample Tracking (Feature coming soon!) Sample bottles with smart tags can easily be tracked with the new Hach RFID* sample-ID system, eliminating sample mix-ups and providing better sample traceability.

General Specifications
Depth 10.04 in
Height5.94 in
Width 13.78 in
Power Requirements Input: 100-240V/50-60 Hz. Output: 15 V/30 VA
Weight9.26 lbs
Wavelength Range320 to 1100 nm
Scanning Speed= 8 nm/s
Light SourceGas-filled Tungsten (visible
OpticsSplit Beam
Stray Light< 0.1 % T at 340 nm with NaNO2
Wavelength Resolution 1 nm
Additional Specifications

Operating Mode: Transmittance (%), Absorbance, and Concentration
Wavelength Accuracy: ± 1.5 nm (wavelength range 340-900 nm)
Wavelength Calibration: Automatic
Wavelength Selection: Automatic, based on method selection
Spectral Bandwidth: 5 nm
User-entered Calibrations: 100
Data Storage: 2000 readings
Automatic Method Recognition: With TNTplus vial tests
10-fold measurement and averaging: With TNTplus vial tests
Display: 7" TFT WVGA (800 pix x 480 pix)
Cell Compatibility: 1" square, 1" round, 1-cm square, 1-cm x 5-cm, Multipath 1"/1-cm, 16-mm round, 13-mm round
Ambient Operating Requirements: 10 - 40 °C (50 - 104 °F), max. 80% relative humidity (non-condensing)
Ambient Storage Requirements: -40 - 60 °C (-40 - 140 °F) max. 80% relative humidity (non-condensing)