Applied Biosystems - 3100-Avant
The upgradeable, four-capillary 3100-Avant Genetic Analyzer gives you the sophisticated automation and superior performance of the 3100 system.
Designed for low- to medium-throughput laboratory needs, the fully automated 3100-Avant system can analyze hundreds of samples per day. Most importantly, as the scale of your research increases, you can upgrade to the 16-capillary 3100 system and quadruple your daily throughput without purchasing an additional instrument.
Active Questions & AnswersAsk a Question
There are no current Discussions
DNA Sequence Analyzers Service ProvidersView All (6)
Documents & Manuals
There are no Documents or Manuals available.
Features of 3100-Avant
- Keep pace with your throughput needs by easily upgrading from 4 to 16 capillary arrays.
- Reduce labor with automated polymer and sample loading and easy-to-use tools to visualize data analysis.
- Perform all your sequencing and genotyping applications quickly, accurately, and reliably on a single instrument
General Specifications
Depth | 22 |
Height | 32 |
Width | 29 |
Power Requirements | 200–220 V or 230–240 V +/–10%; 50/60 Hz +/–10%; Maximum 15 A |
Peak Power | 2000 W |
Weight | 287 lbs |
Additional Specifications
Rapid-mode performance: 98.5% basecalling accuracy with Sequencing Analysis basecaller
Rapid-mode throughput: 48,000 bases/24 hours
Standard-mode performance: 98.5% basecalling accuracy with Sequencing Analysis basecaller
Standard-mode throughput:
23,400 bases/24 hours
93,600 bases/24 hours (9 runs x 16 capillaries x 650 basecalls per capillary)
Long read-mode performance: 98.5% basecalling accuracy with Sequencing Analysis basecaller
Long read-mode throughput:
22,800 bases/24 hours
91,200 bases/24 hours (6 runs x 16 capillaries x 950 basecalls per capillary)
DNA size performance:
Single base detection up to 400 bases with 0.15 standard deviation (36 cm)
Single base detection up to 400 bases with 0.4-0.6 standard deviation (22 cm)
DNA size throughput:
5,760 genotypes/24 hours (22 cm)
2,560 genotypes/24 hours (36 cm)
10,240 genotypes/24 hours (36 cm)
23,400 bases/24 hours
Mutation Performance: Single nucleotide polymorphism identification by five-color fluorescence up to 100 bases
Mutation Throughput: 3,840 genotypes/24 hours
Ultra-rapid mode performance: 98.5% basecalling accuracy with Sequencing Analysis basecaller
Ultra-rapid mode throughput: 288,000 bases/24 hours (36 runs x 16 capillaries x 500 base calls per capillary)
Rapid mode performance: 98.5% basecalling accuracy with Sequencing Analysis basecaller
Rapid mode throughput: 192,000 bases/24 hours (24 runs x 16 capillaries x 500 base calls per capillary)
Long read-mode performance: 98.5% basecalling accuracy with Sequencing Analysis basecaller
Mutation vs performance: Single nucleotide polymorphism identification by five-color fluorescence up to 100 bases
Mutation vs throughput:
7,680 genotypes/24 hours (36 cm)
15,360 genotypes/24 hours (22 cm)